{"product_id":"digital-eeg-system-16-channel-brain-mapping-machine-with-ecg-option-ce-contec-kt88-1016-clinical-electroencephalogram-equipment-for-epilepsy-detection-and-neurological-analysis-24hr-recording-usb-interface","title":"Digital EEG System 16 Channel Brain Mapping Machine with ECG Option, CE CONTEC KT88-1016 Clinical Electroencephalogram Equipment for Epilepsy Detection and Neurological Analysis, 24hr Recording, USB Interface","description":"\u003ch1\u003eCE CONTEC KT88-1016 16-Channel Digital EEG System for Clinical Brain Mapping and Analysis\u003c\/h1\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"CE CONTEC KT88-1016 16-channel digital electroencephalogram and brain mapping system on a stand.\" src=\"https:\/\/images.seoo.uk\/src\/products\/shopify_export\/US10\/1220\/2025-10-02\/original-image\/020bebf9-7fbf-4575-844c-e62672b9688a.webp\"\u003e\u003c\/div\u003e\n\u003cp\u003eThe CE CONTEC KT88-1016 represents a specialised piece of medical diagnostic equipment: a 16-channel digital electroencephalogram (EEG) and brain mapping system. It is engineered to collect, amplify, and analyse the brain's electrical activity through electrodes placed on the scalp. By utilising integrated amplification, analog-to-digital (A\/D) transformation, and computer-based automatic analysis including Fast Fourier Transform (FFT), it generates detailed electroencephalograms displayed with colour depth. This system is designed for clinical settings to assist in the examination and monitoring of neurological conditions such as epilepsy, intracranial inflammation, cerebrovascular diseases, and brain tumours. Its core purpose is to provide clinicians with accurate, analysable data to support diagnostic decisions.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications and Performance\u003c\/h2\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"CE CONTEC KT88-1016 16-channel digital electroencephalogram and brain mapping system on a stand.\" src=\"https:\/\/images.seoo.uk\/src\/products\/shopify_export\/US10\/1220\/2025-10-02\/original-image\/36429d2a-5757-4e1c-af3b-8025717d5ddc.webp\"\u003e\u003c\/div\u003e\n\u003cp\u003eThe KT88-1016 is built to precise technical standards, ensuring reliable signal acquisition and patient safety during extended monitoring periods.\u003c\/p\u003e\n\u003ch3\u003eSignal Acquisition and Channels\u003c\/h3\u003e\n\u003cp\u003eThis system offers 16 dedicated channels for EEG signal acquisition, providing a comprehensive view of electrical activity across the brain. An additional 2 channels for electrocardiogram (ECG) are available as an optional feature, allowing for simultaneous cardiac monitoring where required. The sampling rate is set at 100 dots per second with an accuracy of 12-bit, capturing detailed waveform data. Input impedance is high at ≥10MΩ to minimise signal loss, while patient leak current is kept exceptionally low at \u0026lt; 10µA for safety. The system maintains a high Common Mode Rejection Ratio (CMRR) of ≥90dB and operates with a low noise level of ≤5µV peak-to-peak.\u003c\/p\u003e\n\u003ch3\u003eDisplay and Analysis Controls\u003c\/h3\u003e\n\u003cp\u003eClinicians have full control over the display and analysis parameters. The display speed, analogous to paper speed, is adjustable across a range: 5, 10, 15, 30, 60, and 120 mm\/s. Amplitude can be set to various levels from 1 to 50 mm\/50µV to best visualise the captured waveforms. During playback, the speed can be increased from 1x up to 60x normal speed for efficient review. A digital filter system allows filters to be set as required, and a 50Hz interference suppression of ≥30dB helps clean the signal from common electrical noise.\u003c\/p\u003e\n\u003ch3\u003eSafety and Construction\u003c\/h3\u003e\n\u003cp\u003eSafety is integral to the design. The system is classified as a Class II, type BF applied part, adhering to medical electrical equipment safety standards. It incorporates a professional isolation transformer and a dual power supply isolation system. Data transmission is handled via optoelectronic isolation and a USB interface, which provides both security and convenience. The physical unit is compact, measuring 186 mm in length, 135 mm in width, and 89.2 mm in height, and weighs 550g.\u003c\/p\u003e\n\u003ch2\u003eKey Features and Clinical Functions\u003c\/h2\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"CE CONTEC KT88-1016 16-channel digital electroencephalogram and brain mapping system on a stand.\" src=\"https:\/\/images.seoo.uk\/src\/products\/shopify_export\/US10\/1220\/2025-10-02\/original-image\/3a9f712b-85a3-4ec0-a795-62f175f69d39.webp\"\u003e\u003c\/div\u003e\n\u003cp\u003eBeyond core signal acquisition, the KT88-1016 includes a suite of features designed to enhance clinical workflow, data analysis, and research capabilities.\u003c\/p\u003e\n\u003ch3\u003eRecording and Playback Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe system supports extended, continuous recording sessions of up to 24 hours, facilitated by its bioelectricity amplifier. A powerful playback function allows clinicians to review recordings with adjustable amplitude and display speed. A special feature subdivides the timeline, dividing one second of waveform into five parts for more detailed inspection. The EEG signal clipping function lets users select, analyse, and store any specific section of the EEG wave, and several segments can be chosen for automated parameter extraction.\u003c\/p\u003e\n\u003ch3\u003eAnalysis and Mapping Tools\u003c\/h3\u003e\n\u003cp\u003eAutomatic analysis is a significant strength. The system can perform power spectrum analysis and pathological wave detection on appointed waveforms. It generates various brain mapping displays, including BEAM (Brain Electrical Activity Mapping), numerical BEAM, compressed spectrum graphs, and trend graphs, which can all be displayed on the same screen for comparison. An electronic frequency ruler provides a convenient way to measure period, amplitude, and frequency of any appointed EEG waveform, aided by a partial enlarging window for accuracy.\u003c\/p\u003e\n\u003ch3\u003eData Management and Reporting\u003c\/h3\u003e\n\u003cp\u003eCase management is robust, offering multiple means for research and quick statistical information. Case files can be exported and imported, and stored on removable media like MO or CD-RW disks. Files can also be transformed into standard EDF and BDF data formats, facilitating data exchange and academic collaboration. Reporting is flexible, with an integrative image and character report that can be edited and switched to a Word document. Users can add marks, annotations, and user-defined events (like opening eyes or flashing stimuli) to the waveform, with events marked in different colours for rapid location during playback.\u003c\/p\u003e\n\u003ch2\u003eUsage, Accessories, and Compliance\u003c\/h2\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"CE CONTEC KT88-1016 16-channel digital electroencephalogram and brain mapping system on a stand.\" src=\"https:\/\/images.seoo.uk\/src\/products\/shopify_export\/US10\/1220\/2025-10-02\/original-image\/5a16adea-d928-4471-9c42-53268fac3c63.webp\"\u003e\u003c\/div\u003e\n\u003cp\u003eThe system is designed for practical use in a clinical environment, supported by a full set of accessories and necessary certifications.\u003c\/p\u003e\n\u003ch3\u003eOperational Setup and Environment\u003c\/h3\u003e\n\u003cp\u003eThe KT88-1016 uses the international standard 10\/20 system for electrode placement. Leads can be changed during replay, and different types of combined leads are supported during sampling. It operates using a USB 5V DC power supply. The operational environment must be maintained within a temperature range of +5℃ to +40℃ and a relative humidity of ≤85%. For storage, the environment should be between -20℃ and +55℃ with humidity ≤90%.\u003c\/p\u003e\n\u003ch3\u003eIncluded Accessories and Optional Functions\u003c\/h3\u003e\n\u003cp\u003eThe package includes all standard items needed for setup: an EEG lead, EEG electrodes, a data line, a headgear, a strobe light with its power supply, a user manual, an earth wire, an EEG bracket, and an aluminum block. Optional functions expand its utility. A USB camera can be added for video recording, allowing synchronous waveform and image sampling with flexible playback. An SpO2 function is also available as an optional add-on. A multifunctional USB flash stimulator is included, with flashing that can be controlled manually or automatically according to a set stimulation scheme.\u003c\/p\u003e\n\u003ch3\u003eCertifications and Standards\u003c\/h3\u003e\n\u003cp\u003eThe CE CONTEC KT88-1016 holds relevant medical device certifications, specifically an SFDA certificate and a CMC certificate, confirming it meets the regulatory standards for its intended medical use in applicable markets.\u003c\/p\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"CE CONTEC KT88-1016 16-channel digital electroencephalogram and brain mapping system on a stand.\" src=\"https:\/\/images.seoo.uk\/src\/products\/shopify_export\/US10\/1220\/2025-10-02\/original-image\/604be8ea-68d7-47c3-8650-1f0130e04042.webp\"\u003e\u003c\/div\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"CE CONTEC KT88-1016 16-channel digital electroencephalogram and brain mapping system on a stand.\" src=\"https:\/\/images.seoo.uk\/src\/products\/shopify_export\/US10\/1220\/2025-10-02\/original-image\/60c936f8-8de2-46fb-acc4-e62de2105bbd.webp\"\u003e\u003c\/div\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"CE CONTEC KT88-1016 16-channel digital electroencephalogram and brain mapping system on a stand.\" src=\"https:\/\/images.seoo.uk\/src\/products\/shopify_export\/US10\/1220\/2025-10-02\/original-image\/6c5f4838-63bd-4652-a064-2b505dc8e5eb.webp\"\u003e\u003c\/div\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"CE CONTEC KT88-1016 16-channel digital electroencephalogram and brain mapping system on a stand.\" src=\"https:\/\/images.seoo.uk\/src\/products\/shopify_export\/US10\/1220\/2025-10-02\/original-image\/9c485c9b-6ec5-4a88-8529-33e1f8e7239c.webp\"\u003e\u003c\/div\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"CE CONTEC KT88-1016 16-channel digital electroencephalogram and brain mapping system on a stand.\" src=\"https:\/\/images.seoo.uk\/src\/products\/shopify_export\/US10\/1220\/2025-10-02\/original-image\/cc2395b2-919b-4a98-b23f-ebc9ee096fa9.webp\"\u003e\u003c\/div\u003e","brand":"qydz45-fd","offers":[{"title":"KT88","offer_id":57390634926457,"sku":"CJZN1707371-KT88","price":1242.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0989\/1781\/0553\/files\/6c5f4838-63bd-4652-a064-2b505dc8e5eb.webp?v=1780741994","url":"https:\/\/carovelle.com\/products\/digital-eeg-system-16-channel-brain-mapping-machine-with-ecg-option-ce-contec-kt88-1016-clinical-electroencephalogram-equipment-for-epilepsy-detection-and-neurological-analysis-24hr-recording-usb-interface","provider":"CaroVelle","version":"1.0","type":"link"}